Ipa-tools DTP20C Mobile Fuel Transfer Station Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Ipa-tools DTP20C Mobile Fuel Transfer Station herunter. IPA Tools DTP20C Mobile Fuel Transfer Station User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
TRANSFER RATE: 20 GPM at Level Ambient Load
VOLTAGE: 12 Volt DC
AMPERAGE: 25 Amp Average Draw Ambient
BATTERY TYPE: Two Group 31 in. Threaded Post 12 Volt DC
PNEUMATIC TIRES: 10 in.
OUTLET HOSE: 12 ft. long, ¾ in. Diameter Hard Wall Ground Wire Hose
INLET HOSE: 11 ft. Long, 1 in. Diameter Hose
FUEL FLOW METER: Digital Flow Meter (1 in. Inlet)
BALL VALVE: 1 in. Ball Valve NPT
AXLE SIZE: ½ x 16 in.
VOLT METER: 12 Volt Range
AMP GAUGE: Pos. or Neg. 30 Amp Deflection
CART: Steel Welded Construction
GROUNDING: 10 ft. Chassis Ground Wire
COUNTRY OF ORIGIN: Made and Assembled in USA
DTP20 SERIES
INDUSTRIAL FUEL CLEANER & TRANSFER SYSTEM
DIESEL FUEL ONLY
WARNINGS
ALWAYS KEEP A FIRE EXTINGUISHER RATED FOR FUEL AVAILABLE IN CASE
OF A FIRE.
ALWAYS GROUND CART BEFORE USE.
THE VAPORS CREATED FROM GASOLINE TRANSFER ARE HIGHLY FLAMMABLE
AND CAN BE VERY DANGEROUS. FOR THIS REASON, WE DO NOT RECOMMEND
THIS UNIT FOR GASOLINE.
NEVER LEAVE PUMP RUNNING AND UNATTENDED.
THE INDUSTRIAL FUEL CLEANER & TRANSFER SYSTEM (DTP20) IS NOT RECOM-
MENDED FOR THE FOLLOWING FLUIDS: Acetone, Ammonia, Benzene, Bleach,
Hydrochloric Acid, Ink, Toluene or Gasoline.
SPECIFICATIONS
The DTP20 Series (12V DC powered) INDUSTRIAL FUEL CLEANER & TRANS-
FER SYSTEM is capable of a flow rate up to 20 GPM. To avoid the risk of a fire,
this system is to be used only to transfer and filter diesel, kerosene, and home
heating oil. The in-line filtration system features a 10 micron water-blocking
filter. The cart is designed to hold up to two Group 31, 12 Volt batteries.
INSTR-DTP20B-v11
FOR A WARRANTY CLAIM, RETURN THE ITEM TO:
Innovative Products of America
®
Incorporated Attn: Warranty Repair
234 Tinker Street, Woodstock, NY 12498
888-786-7899 www.ipatools.com
REPLACEMENT PARTS AND WARRANTY SERVICE:
This product has been built with the highest level of quality. However,
certain components wear out over time and may require replacement.
PUMP TURNS ON
AND RUNS BUT
NO PRESSURE.
PUMP NOT
TURNING ON.
PROBLEM POSSIBLE CAUSE REPAIR
AFTER EXTENDED USE
PUMP SHUTS DOWN.
VOLT METER PEGGED
+ or
-
.
SLOW OUTPUT.
Battery low or dead, bad battery
connections, broken wires or wire.
Sear chip broken.
Inlet suction hose is not in transfer uid.
Battery wiring backward.
Filter swelling because of water in
fuel.
After extended use, the pump
incorporates a thermal shutdown
to protect the motor.
Improper battery wiring.
Clogged lter.
Hoses clogged.
Battery voltage low.
Repair broken or poor connections as
required.
Check wiring behind face plate and
connections to the AMP meter and volt
meter.
The sear chip is located under the 4-bolt
end plate on end of pump. The sear chip
connects the motor to the rotor and is
made of a plastic material. If the pump
assembly jams the sear chip will break
before damaging the pump. Replace sear
chip as necessary.
Check uid level.
Check for correct wiring.
Replace lter.
Allow pump to cool and restart the
pump. (This is a normal safety device)
Check and be sure batteries are connected
in “Parallel”. (Fig. 1)
Change the lter.
Check hoses for blockages.
Check battery voltage or re-charge battery.
10. TROUBLESHOOTING
The DTP20 is powered by 12 Volts DC. The cart is capable of utilizing two 12
Volt batteries for extended use. Before the pump is turned on, be sure it is wired
correctly. It is very important that if two batteries are used and they are
connected together in “parallel” configuration, the final voltage should be 12
Volts. If the batteries are wired in series, you will send 24 Volts to the pump and
will burn up the pump. After connecting, look at the volt meter and verify that it
reads in a 12 Volt range.
9. EXTENSION HOSE (OPTIONAL)
An additional 12 ft. extension hose is available to be connected to the output
side of the transfer pump. The extension hose comes with “quick disconnect”
hardware and can be connected to extend the overall reach of the DTP20 Series.
Extension hoses should never be added to the intake side. Doing so will render
the pump ineffective, damage it and void the warranty. Be sure to pin adapters
shut to prevent spillage. Thoroughly drain hose before removing extension.
8 1
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - DIESEL FUEL ONLY

TRANSFER RATE: 20 GPM at Level Ambient LoadVOLTAGE: 12 Volt DCAMPERAGE: 25 Amp Average Draw AmbientBATTERY TYPE: Two Group 31 ⅜ in. Threaded Post

Seite 2 - PARALLEL WIRING

1. BATTERY INSTALLATIONPRIOR TO REMOVING THE BATTERY, BE CERTAIN TO COMPLETELY CLEAN ANY FUEL OIL IN THE BATTERY AREA. AVOID ARCING! TO REMOVE

Seite 3 - FRONT VIEW

6 33. FUEL TRANSFER AND OPERATIONAL USEAfter setting up the DTP20 according to the directions and safety instructions, you are now ready to transfer f

Seite 4 - 8. TIRES MAINTENANCE

4 55. METERSThe Amp Meter displays the amount of current the pump is drawing from the batteries. Several factors affect the amount of current drawn fr

Kommentare zu diesen Handbüchern